Case Study: Proactive Motor Testing Protects Ethanol Plant

Ethanol has been a clean-burning fuel used in the United States since the 1850s. Ford’s Model T automobile was designed to run on ethanol, and while ethanol was banned during the Prohibition era, it gained traction in the 1970s at a time of high gas prices and concern around oil imports. Ethanol made a major come-back when the Renewable Fuel Standard was initiated by Congress in 2005 to set some minimum requirements for using renewable fuels, and now, about 14 billion gallons of ethanol are added per year to gasoline consumed nationwide.

 

The Company:

One of the companies dedicated to contributing to America’s sources of renewable energy is Cardinal Ethanol. In 2008, Cardinal Ethanol commissioned a natural gas fired ethanol producing plant in the heart of the Corn Belt. Located in Indiana, this ethanol plant produces approximately 100 million gallons of ethanol per year, in addition to 340K tons of dried distillers grains with solubles that are distributed to companies who produce food for livestock and poultry.

In order to produce 100 million gallons of ethanol per year, the plant has to ensure their equipment operates reliably 24 hours a day, 7 days a week. The in-house maintenance team at the ethanol plant schedules “planned shutdowns” twice each year, once in the spring and once in the fall, to perform maintenance on the equipment and machinery operating in the plant. During the fall 2015 shutdown, four new motors were installed to drive the conveyor belts that fed the corn in through to the ethanol processing plant.

In December 2015, the maintenance team noticed the grain flow was being interrupted. Mark Durr, Maintenance Project Manager at the ethanol plant, swiftly investigated the grain delivery system and determined that the interruptions in grain flow were being caused by intermittent shutoff of the conveyors. Mark then instructed his in-house maintenance team to perform several tests on all four motors that drive the corn conveyors.

 

Motor Testing to Prevent Unplanned Shutdown:

“I instructed my Technicians to test all four motors, which ranged from 40- to 60-horsepower, and our meg-ohm meter showed the coils were fine, no short turns and nothing going to ground,” explains Mark. “When we used the ALL-TEST Pro 33 IND™, that motor testing instrument showed us the rotors were bad.”

Mark immediately contacted the general contractor who had installed the motors to inform him of his discovery. The contractor was curious about Mark’s conclusion that there was a problem with the rotors. The motors were brand new, and the contractor could not believe that all four motors would have rotor problems. When asked how he came to this conclusion about the rotors being the root cause of the problem, Mark explained to the contractor that he had an AT33™, which is a de-energized motor testing instrument that shows the complete condition of the both the stator windings and the rotor.

“I had purchased the AT33™ motor testing instrument a little over a year ago, shortly after I began working at this plant. We are focused on preventive maintenance to keep this plant up and running, and that means having the right tools to prevent plant shutdowns,” states Mark. “When you have a problem with a motor, a meg-ohm meter, multi-meter, and LCR meter (L-inductance, C-capacitance, R-resistance) are not going to tell you if there is a problem with a rotor, but an AT33™ will.”

After the motor testing results were shared with the contractor, the contractor made arrangements to replace the motors, which had been under warranty. The motors that had been tested with the AT33™ were sent to the contractor’s service center to be disassembled and inspected. The service center technicians confirmed that the rotors had in fact been the root cause of the motors’ inability to perform as intended.

“The report from the service center, confirming the rotors were bad, was not a surprise to me,” shares Mark. “We have used the AT33™ quite successfully on several motors, because we know that more common testers don’t have the capability to show rotor health. This is one of the main reasons I bought the AT33™, because of its ability to test the rotor. In this case, it really came in handy.”

 

Lessons Learned - Motors Should Be Tested Prior to Installation:

It is critical to inspect new motors and stored motors before they are installed into a system. Spending a few minutes to test a motor before installing it can save thousands of dollars in maintenance, and in some cases, shutdown costs.

The AT33™ de-energized motor testing instrument, which performs both Static and Dynamic tests, is a proven asset for revealing the complete condition of the motor rotor and stator windings and also helps the maintenance technician or operator understand if there are any issues with contamination, connections, and ground faults.

 

Authors: Mark S. Durr, Maintenance Project Manager, Cardinal Ethanol LLC., Mike Schneider, Regional Manager, ALL-TEST Pro LLC.

 


 

Variable Frequency Drives 101

Utilizing pumps on a regular basis can be a costly operation; they can run for hours at a time and require a tremendous amount of power to run. We all know (or might not know) that energy efficiency starts with motor speed control. To keep things...

IWAKI AIR AODD Pumps now at JETT Pump

  JETT Pump & Valve, LLC now proudly distributes IWAKI AIR! Iwaki Air AODD pumps or Air Operated Diaphragm pumps are engineered for maximum utility. They are portable and easy to install, operate, and maintain. Infinitely variable...

How to Read Pump Curves

Pump Curves for Pump Selection 101 For those in the pump industry, learning how to read a pump curve or performance curve can be incredibly useful if not downright necessary. For us here at JETT Pump, one of the ways we apply our knowledge...

What Happens After the Flush

What Happens After the Flush? “Outta sight, outta mind” is the attitude most of us have when flushing a toilet. We don’t want to think about it or ask about it, but someone has to answer it. So what really happens after you...

#TBT JETT Pump Solves Clogging

Costly Clogging Problem Solved by Barnes SH Pumps #TBT Throwback Thursday! Back in 2010 the City of Inkster, MI was experiencing persistent recurring clogging- almost every 48 hours! And sometimes after only ten minutes of being unclogged!! The...

Preventative Motor Testing

JETT Pump & Valve, LLC Adds Preventative Motor Testing Waterford, MI March 1, 2016, JETT Pump & Valve, LLC is pleased to announce that they have added a new manufacturer, ALL-TEST Pro, LLC to their extensive product line. This new...

Walchem Liquidation Sale

Walchem On Sale - Going on NOW! Check out the start of our Walchem Liquidation Sale on eBay! There are some new in box older model metering pumps posted right now, take a look! JETT Pump on eBay    

Learning About Lift Stations

Lift Stations: The Basics JETT Pump & Valve, LLC provides a variety of services for municipal, industrial, and commercial customers. Lift stations are commonly our patients for the services we preform. Most people are not familiar with what a...

7 Deadly Toilet Sins

Don't Flush This! The universe gave us both toilets and trash cans, and each are to be used responsibly! When you flush things down the toilet, they simply don’t just disappear. By doing so, you are allowing it to enter into the...

Welcome to Our New Website!

We've added great new features and updated our content to bring you the most up to date information about our company.  Check back often for updates.
Page: 123 - All